Saltee Plaza, 1 K B Sarani, Room 313, Kolkata 700080Call +91 93306 64877sadguru.laboratory@gmail.com
IS 10500

Drinking water testing against IS 10500

IS 10500 is the Indian standard for drinking water. A full test covers physical, chemical and bacteriological parameters, each with an acceptable limit and a permissible limit in the absence of an alternate source. We report all three groups on one report with the method used for each.

Standard
IS 10500
Sample needed
2 L + 250 ml sterile
Groups
Physical · chemical · bacteriological
Report
Method, limit and result per line

Parameters and limits we report

The limits below are those specified in IS 10500. "No relaxation" means the permissible limit is the same as the acceptable limit — there is no second tier.

ParameterUnitAcceptable limitPermissible limitGroup
pH value6.5 – 8.5No relaxationPhysical
TurbidityNTU15Physical
Total dissolved solidsmg/L5002000Physical
Total hardness (as CaCO₃)mg/L200600Chemical
Chloride (as Cl)mg/L2501000Chemical
Sulphate (as SO₄)mg/L200400Chemical
Iron (as Fe)mg/L1.0No relaxationChemical
Fluoride (as F)mg/L1.01.5Chemical
Nitrate (as NO₃)mg/L45No relaxationChemical
Arsenic (as As)mg/L0.010.05Chemical
Lead (as Pb)mg/L0.01No relaxationChemical
Total coliformMPN/100 mlShall not be detectableNo relaxationBacteriological
E. coliper 100 mlShall not be detectableNo relaxationBacteriological

What to send us

Quantity
2 litres for chemical analysis, plus 250 ml in a sterile bottle for the bacteriological test
Container
Clean food-grade bottle for chemical; sterile bottle only for bacteriological — we supply these free
Hold time
Bacteriological samples must reach us within 24 hours, kept cool
Full collection instructions →

What if a parameter fails?

The report tells you which parameter exceeded which limit and by how much. That is what a plumber, an RO vendor or a consultant needs to size a fix. We do not sell treatment equipment, so the result carries no commercial interest for us. In Kolkata the two most common failures we see are iron in borewell water and coliform in overhead tanks that have not been cleaned — different problems with completely different remedies.

Questions about this test

Should I test the tank or the tap?

Both, if you are diagnosing a complaint. A clean reservoir with a contaminated tap points at the internal plumbing; contamination at both points at the source or the tank. Testing only one point tells you there is a problem but not where it is.

Is a TDS meter enough?

No. A TDS meter measures dissolved solids and nothing else. It cannot detect arsenic, lead, fluoride, nitrate or bacteria — the parameters that actually cause harm. Low TDS water can be unsafe and high TDS water can be safe.

How many parameters should I test?

For a routine safety check, the bacteriological pair plus pH, TDS, hardness and iron answers most questions cheaply. For a formal submission or a health concern, run the full panel including heavy metals.

Request this testAsk on WhatsAppUpdated 16 September 2026