IS 10500 is the Indian standard for drinking water. A full test covers physical, chemical and bacteriological parameters, each with an acceptable limit and a permissible limit in the absence of an alternate source. We report all three groups on one report with the method used for each.
Standard
IS 10500
Sample needed
2 L + 250 ml sterile
Groups
Physical · chemical · bacteriological
Report
Method, limit and result per line
Parameters and limits we report
The limits below are those specified in IS 10500. "No relaxation" means the permissible limit is the same as the acceptable limit — there is no second tier.
Parameter
Unit
Acceptable limit
Permissible limit
Group
pH value
—
6.5 – 8.5
No relaxation
Physical
Turbidity
NTU
1
5
Physical
Total dissolved solids
mg/L
500
2000
Physical
Total hardness (as CaCO₃)
mg/L
200
600
Chemical
Chloride (as Cl)
mg/L
250
1000
Chemical
Sulphate (as SO₄)
mg/L
200
400
Chemical
Iron (as Fe)
mg/L
1.0
No relaxation
Chemical
Fluoride (as F)
mg/L
1.0
1.5
Chemical
Nitrate (as NO₃)
mg/L
45
No relaxation
Chemical
Arsenic (as As)
mg/L
0.01
0.05
Chemical
Lead (as Pb)
mg/L
0.01
No relaxation
Chemical
Total coliform
MPN/100 ml
Shall not be detectable
No relaxation
Bacteriological
E. coli
per 100 ml
Shall not be detectable
No relaxation
Bacteriological
What to send us
Quantity
2 litres for chemical analysis, plus 250 ml in a sterile bottle for the bacteriological test
Container
Clean food-grade bottle for chemical; sterile bottle only for bacteriological — we supply these free
Hold time
Bacteriological samples must reach us within 24 hours, kept cool
The report tells you which parameter exceeded which limit and by how much. That is what a plumber, an RO vendor or a consultant needs to size a fix. We do not sell treatment equipment, so the result carries no commercial interest for us. In Kolkata the two most common failures we see are iron in borewell water and coliform in overhead tanks that have not been cleaned — different problems with completely different remedies.
Questions about this test
Should I test the tank or the tap?
Both, if you are diagnosing a complaint. A clean reservoir with a contaminated tap points at the internal plumbing; contamination at both points at the source or the tank. Testing only one point tells you there is a problem but not where it is.
Is a TDS meter enough?
No. A TDS meter measures dissolved solids and nothing else. It cannot detect arsenic, lead, fluoride, nitrate or bacteria — the parameters that actually cause harm. Low TDS water can be unsafe and high TDS water can be safe.
How many parameters should I test?
For a routine safety check, the bacteriological pair plus pH, TDS, hardness and iron answers most questions cheaply. For a formal submission or a health concern, run the full panel including heavy metals.